Technical specifications¶
Device¶
SIZE: 180mm x 130mm x 35mm
BATTERY SYSTEM: Lithium-Ion (Li-ion)
- Nominal Voltage: 2 x 3.7V 
- Rated Capacity: 2 x 2.2Ah 
- Wh rating: 2 x 8,14Wh 
CAMERA:
Trapview standard: 4 x 2Mpix
Trapview+: 4 x 5Mpix
MODEM:
Trapview standard:
| Simtech SIM900 | 
|---|
| Quad-Band 850/900/1800/1900MHz | 
| GPRS multi-slot class 10/8 | 
| GPRS mobile station class B | 
| 
 | 
| Dimensions: 24mm × 24mm × 3mm | 
| Control via AT commands (GSM 07.07, 07.05 and SIMCOM enhanced AT Commands) | 
| SIM application toolkit | 
| Supply voltage range: 3.4V to 4.5V | 
| Low power consumption: 1.5mA (sleep mode) | 
| Operation temperature range: -30°C to +80°C | 
Trapview+:
| Cinterion PHS8 - P | 
|---|
| Five Bands UMTS/HSPA+ (WCDMA/FDD) (850/800, 900,1900 and 2100MHz), Quad-Band GSM (850/900/1800/1900MHz) | 
| mark “W” on the electronics (for global market) | 
| Cinterion PHS8 - E | 
|---|
| Dual Band UMTS/HSPA+ (900/2100 MHz), Dual-Band GSM (900/1800 MHz) | 
| mark “E” on the electronics (for EU market) | 
| Technical specifications for both Cinterion modems: | 
| UMTS / HSPA+, 3GPP release 6 / 7 | 
| GSM / GPRS / EDGE, 3GPP release 99 / 4 | 
| RoHS and WEEE compliant | 
| Dimensions: 29mm x 33mm x 2mm | 
| Data, Voice and TTY support | 
| Control via standardized and extended AT commands (Hayes, TS 27.007, TS 27.005) | 
| SIM Application Toolkit, 3GPP release 99 | 
| Supply voltage range: 3.3V to 4.2V | 
| Highly optimized for minimal power consumption | 
| Operation temperature range: -40°C to +85°C | 
Solar panel¶
| SMALL | LARGE | 
|---|---|
| Pmax: 2W | Pmax: 4W | 
| Tolerance: ± 5% | Tolerance: ± 3% | 
| Voltage at maximum output (Vmp): 6V | Voltage at maximum output (Vmp): 6V | 
| Amperage at maximum output (Imp): 0.333A | Amperage at maximum output (Imp): 0.66A | 
| Voltage at open circuit (Voc): 7.1V | Voltage at open circuit (Voc): 7.2V | 
| Short circuit current (Isc): 0.349A | Short circuit current (Isc): 0.8A | 
| Size: 180mm x 130mm x 18mm | Size: 200mm x 180mm x 18mm | 
Large solar panel is usually used with Trapview AURA devices, where more power is needed.
Humidity and temperature sensor¶
- Rh accuracy: ± 4.5%RH 
- T accuracy: ± 0.5°C 
- Operating range: 0 to 100%RH; -40°C to +123.8°C (-40°F to +254.9°F) 
- Power consumption: 3mW measuring; 2-5µW sleep mode 
- Source voltage: 2.4V to 5.5V 
Motor¶
Voltage: 3V Size: Ø24.4mm x 30.8mm